Product Description
Impulse surge can cause damage to electronic appliances in L.V. supply systems, and to protect these appliance against the damage, use P-k16-k16/* AC/DC is type 3 surge arresters according to EN 61643-11 and IEC 61643-1. These can be mounted conveniently on DIN rail 35mm for nominal current of 16A. This range is suitable for nominal voltage within the range of 12, 24, 48, 60 and 110V AC/DC. The green LED diode indicates the right function of P-k16/ *AC/DC. Their low voltage protection level is beneficial for terminal equipment as these equipment are protected in industrial electronics and building management systems. The inputs/output terminals for series connection & the protective circuit are meant for high line currents.
Specifications:- Type: P-k16/60 AC/DC P-k16/110 AC/DC P-k16/230 AC/DC SPD according to IEC 61643-1/-11 Class III Class III Class III SPD according to EN 61643 Type 3 Type 3 Type 3 LPZ 2???3 2???3 2???3 Nominal voltage (UN) 60 V 110 V 230 V
- Maximum continuous operating A.C. voltage: (UC) 75 AC 150 AC 255 AC
- Maximum continuous operating D.C. voltage: (UC) 90 V DC 180 V DC 310 V DC
- Nominal load current: (IL) 16 A 16 A 16 A
- Nominal discharge current: (8/20 s) (In) 0.7 kA 1 kA 2.5 kA
- Maximum discharge current: (8/20 s) (Imax) 2.5 kA 2.5 kA 2.5 kA
- Combined impulse: (Uoc) 4 kV 6 kV 6 kV
- Total Combined impulse: (Uoc total) 8 kV 8 kV 10 kV
- Voltage protection level: (L/N) (UP) < 400 V < 440 V < 950 V
- Voltage protection level at (L/PE): (UP) < 730 V < 800 V < 1500 V
- Response time: (L/N) (tA) < 25 ns < 25 ns < 25 ns
- Response time: (L/PE) (tA) < 100 ns < 100 ns < 100 ns
- Operating Indication (LED): Green-Ok/Red-Fault Green-Ok/Red-Fault Green-Ok/Red-Fault
- Maximum backup fuse: 16 AgL/gG 16 AgL/gG 16 AgL/gG
- Operating temperature range: -40 degrees Celsius...+80 degrees Celsius -40degrees Celsius ...+80 degrees Celsius -40degrees Celsius ...+80 degrees Celsius
- Degree of protection: IP 20 IP 20 IP 20
- Connection cross-sectional area (flexible): 0.14 - 2.5 mm2 0.14 - 2.5 mm2 0.14 - 2.5 mm2
- Connection cross-sectional area (Solid): 0.14 - 2.5 mm2 0.14 - 2.5 mm2 0.14 - 2.5 mm2
- Connection cross-sectional area (multi-wire): 0.14 - 2.5 mm2 0.14 - 2.5 mm2 0.14 - 2.5 mm2
- Mounting arrangement: 35 mm DIN rail according to EN 60715 35 mm DIN rail according to EN 60715 35 mm DIN rail according to EN 60715
- Housing material: Polyamide PA6, UL 94 V-0 Polyamide PA6, UL 94 V-0 Polyamide PA6, UL 94 V-0
- Number of port: 1 1 1
- Weight m: 90 g 90 g 90 g
- Article number: 30 018 30 020 -------
Superior Surge Protection for DC ApplicationsDesigned specifically for single-phase DC power systems and solar PV installations, this surge protective device safeguards critical equipment from surge events. Its precise and rapid response, paired with high efficiency and overheating protection, ensures ongoing system reliability while meeting international safety and environmental standards.
Effortless Installation and OperationThis SPD offers a straightforward screw terminal connection and fits standard DIN rail mounting. The integrated end-of-life indicator and optional remote signaling simplify maintenance. With a compact, lightweight body and matte finish, it integrates smoothly into any DC power setup, supporting environmental requirements with RoHS compliance.
FAQs of DC SPD (Type 3 ):
Q: How does the Type 3 DC SPD protect my solar PV system?
A: The device quickly diverts surge currentsup to 20 kAaway from sensitive equipment, limiting the voltage let-through to 2.0 kV. Its rapid response time of less than 25 nanoseconds ensures that even transient surges are mitigated, minimizing damage to PV components and maintaining operational stability.
Q: What is the recommended process for installing this SPD?
A: The SPD is designed for standard DIN rail mounting and uses screw terminals for easy electrical connections. Ensure the system is powered down before installation, mount the device securely, connect the two poles to the relevant DC lines, and follow manufacturer guidelines for safety and optimal protection.
Q: When should the SPD be replaced or serviced?
A: The integrated end-of-life indicator alerts users when the SPD can no longer provide effective protection. Routine visual inspections are recommended, and remote signaling (if used) can also notify maintenance teams. Replacement should occur promptly if the indicator signals end of life or after a major surge event.
Q: Where is this SPD commonly used?
A: This SPD is ideal for use in solar photovoltaic systems and DC power distribution panels. Its design supports single-phase DC applications up to 1000 V DC, making it suitable for renewable energy setups, commercial installations, and industrial environments.
Q: What are the environmental and safety benefits of this SPD?
A: Constructed with lead-free, RoHS-compliant, PC flame-retardant materials, it contributes to eco-friendly installations while ensuring fire safety. The SPD provides reliable protection without compromising environmental standards or system efficiency.
Q: How much energy does the SPD consume during operation?
A: The device is highly efficient, consuming less than 1 Watt during operation while maintaining a protection efficiency of over 98%. This low power consumption ensures minimal impact on total system energy usage.